The generator is based on the principle of "electromagnetic induction" discovered in 1831 by Michael Faraday, a British scientist. Faraday discovered that if an electric conductor, like a copper wire, is moved through a magnetic field, electric current will flow (be induced) in the conductor. So the mechanical energy of the moving wire is converted into the electric energy of the current that flows in the wire.

In electricity generation, an electrical generator is a device that converts mechanical energy to electrical energy, generally using electromagnetic induction. The reverse conversion of electrical energy into mechanical energy is done by a motor; motors and generators have many similarities. A generator forces electric charges to move through an external electrical circuit, but it does not create electricity or charge, which is already present in the wire of its windings. It is somewhat analogous to a water pump, which creates a flow of water but does not create the water inside. The source of mechanical energy may be a reciprocating or turbine steam engine, water falling through a turbine or waterwheel, an internal combustion engine, a wind turbine, a hand crank, compressed air or any other source of mechanical energy.

Before the connection between magnetism and electricity was discovered, electrostatic generators were invented that used electrostatic principles. These generated very high voltages and low currents. They operated by using moving electrically charged belts, plates and disks to carry charge to a high potential electrode. The charge was generated using either of two mechanisms:

Because of their inefficiency and the difficulty of insulating machines producing very high voltages, electrostatic generators had low power ratings and were never used for generation of commercially-significant quantities of electric power. The Wimshu

rst machine and Van de Graaff generator are examples of these machines that have survived.

Dynamo

The Dynamo was the first electrical generator capable of delivering power for industry. The dynamo uses electromagnetic principles to convert mechanical rotation into a pulsing direct electric current through the use of a commutator. The first dynamo was built by Hippolyte Pixii in 1832.

Through a series of accidental discoveries, the dynamo became the source of many later inventions, including the DC electric motor, the AC alternator, the AC synchronous motor, and the rotary converter.

A dynamo machine consists of a stationary structure, which provides a constant magnetic field, and a set of rotating windings which turn within that field. On small machines the constant magnetic field may be provided by one or more permanent magnets; larger machines have the constant magnetic field provided by one or more electromagnets, which are usually called field coils.

Large power generation dynamos are now rarely seen due to the now nearly universal use of alternating current for power distribution and solid state electronic AC to DC power conversion. But before the principles of AC were discovered, very large direct-current dynamos were the only means of power generation and distribution. Now powe

r generation dynamos are mostly a curiosity.


electromagnetic generators

Without a commutator, the dynamo is an example of an alternator, which is a synchronous singly-fed generator. With an electromechanical commutator, the dynamo is a classical direct current (DC) generator. The alternator must always operate at a constant speed that is precisely synchronized to the electrical frequency of the power grid f

or non-destructive operation. The DC generator can operate at any speed within mechanical limits but always outputs a direct current waveform.

Other types of generators, such as the asynchronous or induction singly-fed generator, the doubly-fed generator, or the brushless wound-rotor doubly-fed generator, do not incorporate permanent magnets or field windings (i.e, electromagnets) that est

ablish a constant magnetic field, and as a result, are seeing success in variable speed constant frequency applications, such as wind turbines or other renewable energy technologies.

The full output performance of any generator can be optimized with electronic control but only the doubly-fed generators or the brushless wound-rotor doubly-fed generator incorporate electronic control with power ratings that are substantially less than the power output of the generator under control, which by itself offer cost, relia

bility and efficiency benefits.

magnetohydrodynamic generator


A magnetohydrodynamic generator directly extracts

electric power from moving hot gases through a magnetic field, without the use of rotating electromagnetic machinery. MHD generators were originally developed because the output of a plasma MHD generator is a flame, well able to heat the boilers of a steam power plant. The first practical design was the AVCO Mk. 25, developed in 1965. The U.S. government funded substantial development, culminating in a 25MW demonstration plant in 1987. In the Soviet Union from 1972 until the late 1980s, the MHD plant U 25 was in regular commercial operation on the Moscow power system with a rating of 25 MW, the largest MHD plant rating in the world at that time.MHD generators operated as a topping cycle are currently (2007) less efficient than combined-cycle gas turbines.

Excitation

An electric generator or electric motor that uses field coils rather than permanent magnets will require a current flow to be present in the field coils for the device to be able to work. If the field coils are not powered, the rotor in a generator can spin without producing any usable electrical energy, while the rotor of a motor may not spin at all. Very large power station generators often utilize a separate smaller generator to excite the field coils of the larger.

In the event of a severe widespread power outage where islanding of power stations has occurred, the stations may need to perform a black start to excite the fields of their largest generators, in order to restore customer power service.


Equivalent circuit


The equivalent circuit of a generator and load is shown in the diagram to the right. To determine the generator's VG and RG parameters, follow this procedure: -

  • Before starting the generator, measure the resistance across its terminals using an ohmmeter. This is its DC internal resistance RGDC.
  • Start the generator. Before connecting the load RL, measure the voltage across the generator's terminals. This is the open-circuit voltage VG.
  • Connect the load as shown in the diagram, and measure the voltage across it with the generator running. This is the on-load voltage VL.
  • Measure the load resistance RL, if you don't already know it.
  • Calculate the generator's AC internal resistance RGAC from the following formula:

R_{GAC} = {R_L} \left( {{{V_G}\over{V_L}}-1} \right)

The AC internal resistance of the generator when running is generally slightly higher than its DC resistance when idle. The above procedure allows you to measure both values. For rough calculations, you can omit the measurement of RGAC and assume that RGAC and RGDC are equal.

If the generator is an AC type, use an AC voltmeter for the voltage measurements.

The maximum power theorem states that the maximum power can be obtained from the generator by making the resistance of the load equal to that of the generator. This is inefficient since half the power is wasted in the generator's internal resistance; practical electric power generators operate with load resistance much higher than internal resistance, so the efficiency is greater.